After the purchased heating tube is delivered to express delivery or logistics transportation, or if it is not heated during use on the equipment, how to judge whether the heating tube is damaged?
Very simple method: Our usual practice is to use a resistance meter to measure whether there is a resistance value. If there is no resistance value, it means that the heating tube is broken. (In the course of transportation, especially in the case of irresponsible express delivery or logistics dumping, there will be damage to the heating tube.)
Conversely: if there is a resistance value, but the heating tube on the equipment trips after the leakage protection is turned on after the switch is turned on, then use the insulation resistance meter to measure the insulation resistance value. The insulation resistance no longer exists, indicating that the pipe has leaked and cannot be used anymore.
Of course, specific problems need to be analyzed in detail. Whether it is the main factor or the external factor, the quality of the heating tube has a direct relationship with the manufacturer, and we must be cautious in product selection.