+8613456528940

What is a thermocouple, and what is the purpose and principle of a thermocouple?

Dec 08, 2021

The basic principle of thermocouple temperature measurement

    Two conductors of different materials or semiconductors A and B are welded together to form a closed loop. When there is a temperature difference between the two attachment points 1 and 2 of conductors A and B, an electromotive force is generated between the two, thus in the loop A large current is formed in the pyroelectric effect. This phenomenon is called the pyroelectric effect. Thermocouples use this effect to work.


    What is a thermocouple?


    Both thermocouples and thermal resistances belong to contact temperature measurement in temperature measurement. Although their functions are the same to measure the temperature of an object, their principles and characteristics are different.


    Thermocouple is the most widely used temperature device in temperature measurement. Its main characteristics are wide measuring range, relatively stable performance, simple structure, good dynamic response, and the ability to transmit 4-20mA electrical signals remotely, which is convenient for automatic control and concentration. control. The principle of thermocouple temperature measurement is based on the thermoelectric effect. Two different conductors or semiconductors are connected into a closed loop. When the temperatures at the two junctions are different, thermoelectric potential will be generated in the loop. This phenomenon is called the pyroelectric effect, also known as the Seebeck effect. The thermoelectric potential generated in the closed loop is composed of two kinds of electric potential; thermoelectric potential and contact potential. Thermoelectric potential refers to the electric potential generated by the two ends of the same conductor due to different temperatures. Different conductors have different electron densities, so they generate different electric potentials. The contact potential, as the name implies, refers to when two different conductors are in contact. Because their electron densities are different, a certain amount of electron diffusion is produced. When they reach a certain equilibrium, the potential formed by the contact potential depends on the material properties of the two different conductors and the temperature of their contact points. At present, thermocouples used internationally have a standard specification. The international regulations stipulate that thermocouples are divided into eight different divisions, namely B, R, S, K, N, E, J and T. The lowest possible measurement temperature Measured at minus 270 degrees Celsius, up to 1800 degrees Celsius, of which B, R, and S belong to the platinum series of thermocouples. Because platinum is a precious metal, they are also called precious metal thermocouples and the remaining ones are called cheap metal thermoelectrics. I. There are two types of thermocouples, common type and armored type. Ordinary thermocouples are generally composed of thermode, insulating tube, protective sleeve and junction box, while armored thermocouple is a combination of thermocouple wire, insulating material and metal protective sleeve. A solid combination formed by stretching. But the electrical signal of the thermocouple needs a special wire to transmit, this kind of wire is called compensation wire. Different thermocouples require different compensation wires, and their main function is to connect with the thermocouple to keep the reference end of the thermocouple away from the power supply, so that the temperature of the reference end is stable. Compensation wires are divided into two types: compensation type and extension type. The chemical composition of the extension wire is the same as that of the thermocouple being compensated. However, in practice, the extension wire is not made of the same material as the thermocouple. Replace with wires with the same electron density. The connection between the compensation wire and the thermocouple is generally very clear. The positive pole of the thermocouple is connected to the red wire of the compensation wire, and the negative pole is connected to the remaining color. Most of the general compensation wires are made of copper-nickel alloy.


Send Inquiry