Some Suggestions on the Modification of the National Standard for Electric Heating Tubes

Aug 17, 2021

The national standard of electric heating tube has reached the stage where it must be revised. As for the electric heating tube, which is the main component of civil or industrial electric heating, it can be said that it has been reviewed from the historical background of the formulation of the national standard content at that time and the current technology and material conditions. Severe lag, and international standards have no detailed standards for its components so far. The measurement standards for product quality in the industry are basically to meet the needs of users. There are many corporate standards and even non-electric heating component manufacturers such as thermostats. Manufacturers are also formulating so-called industry standards that are applicable to the protection of their components. Generally speaking, they are very confusing. The revision of the new national standard focuses on safety and energy saving as the general principle. However, the personal tendencies of the details are as follows: Focus:


(1) Safety indicators for online working status


The safety of the electric heating tube is not only from its normal indicators, such as the level of withstand voltage, the size of the insulation value and other indicators can reflect the essence of the electric heating tube. Its unsafe factors are basically from the working state of the electric heating tube. It can be revealed, so the normal index requirements in the original national standard, one is that there is no need to set too many so-called high standards, and there is no too reliable inevitability between them; and the hot state is the usual online work. The basic requirements, whether it is content items or non-standard indicators, are actually too lacking in the original national standard or there are almost no vacancies in the standard indicators. This is a big problem, and it is also the focus of this revision. However, it is difficult for the organizer to implement it as a standard. The key point is that there are too many types of electric heating tubes, and the other is the scientific nature of the basis. There is a certain amount of work in the qualitative process, such as the same two. When the tube is empty, and the power has a big difference, how to determine the standard of working leakage current at this time? Moreover, although the reliability of the thermal state index as a safety index of the electric heating tube is very high, as an industrialized mass production product, it must be completely relied on as a quality inspection, and there are certain limitations in the method, namely Practical methods and methods must have a synchronization scheme to ensure the value of implementation, otherwise they will still not be popular.


(2) From the viewpoint of energy saving to enhance the test items, it is of great significance to the reliability of quality measurement


The performance of the electric heating tube needs to be tested through the online working status to get a reliable conclusion. Due to the quality of its design, craftsmanship and material quality, it is impossible to obtain a reliable conclusion visually, and at present, low-carbon and energy-saving is the main social project. In the implementation of the transition, the national standard considers the value of this document for the vacancy of this item. insufficient. The energy-saving standard is based on the level of electric heating efficiency. On the one hand, it can reflect the true situation of the product, and at the same time, it can reflect the true status of a manufacturer's technical process and equipment capabilities, including integrity. For this part of the content, the detection methods are relatively simple and easy to operate. The non-standard determination can be defined according to the current filling material equipment capabilities. In these aspects, it can also be adjusted in time with technological progress. , The author agrees with this, and during testing, only random inspections can reflect the real quality status. The specific index is recommended to be above 94.5%, which is more realistic.


(3) Consistency between the content of the national standard and the international standard


The content of the national standard implemented last time has a certain gap with the international standard in terms of dimensionality and practicability. The analysis from the indicator data alone seems to be high in some content. The single article does not reflect the advanced nature, but is correct. Manufacturers and users are somewhat misleading. For example, the normal insulation index is set to DC500V》10M, and the international standard has already adopted the 2M standard, because their normal value and the real work safety of the original are not too good. More relevance. At this time, please also explain that the standards of some professional products in the industry, such as the detection methods and standards of the water boiler series, if they are used simultaneously with these matching thermostats, the matrix detection method at this time has a high reference value. , And if it is used as a single device as a review standard, it is still unfounded, so the definition of component or appliance needs further exploration.


The above content is the author's suggestion for the revision of the new standard, in order to hope that colleagues will put forward relevant content with practical value, and hope that the new standard after this revision will become an advanced and practical new regulation to lead the healthy development of industry norms.