Recently, customers and friends often consult Teflon heat exchangers, and they will inevitably ask about the installation steps and operating methods. Today, the editor will briefly introduce the installation steps and usage methods of the Teflon heat exchanger:
1. During the heating process, the electric heating tube should not be extracted from the liquid. The electric heating tube should be extracted after the electric heating tube is purely cooled after the power is cut for a few minutes.
2. Make sure that the hot part of the tube must be immersed in the solution, otherwise the electric heating tube will be destroyed due to dry burning. The syrup should be added as soon as possible during the production process to maintain the calibration liquid level.
3. Keep a certain distance between the electric heating tubes during installation. If they are close to each other, they may be burnt due to overheating.
4. When used for high-solution heating, the electric heating tube must be washed with water from the tank when the office is stopped, to prevent the solution sediment from crystallizing and agglomerating on the electric heating tube at low temperatures, otherwise it will be heated due to poor heat dissipation. Pipe destroyed.
5. Teflon heat exchangers are generally distributed along the length or width of the tank, and are evenly distributed on one or both sides that will not be touched by the office during operation. They are installed against the wall of the tank. In the electrolytic tank, they can be placed on the plate and the tank. Between the walls.
6. Teflon heat exchangers can be installed with groove edge fixing, groove wall fixing, and hanging on the rod. The wiring installation plate and supporting parts are equipped with drills and bolts are used.
7. When wiring all electric heating tubes, pay attention to the three-phase balance, do not connect the 220v or 380v power supply incorrectly, and must be safely grounded through the leakage switch.