Reference for the repair plan after the electric heating tube is corroded

Aug 14, 2021

Metal electric heating tubes work in the equipment, especially when they are immersed in liquid for a long time. The surface of the electric heating tube is stainless steel. The severity of the situation will be different due to different degrees of corrosion. The electric heating tube will gradually expand and cause leakage due to corrosion. The final result is that the electric heating tube is damaged and cannot be used.


Electric heating tubes can usually be corrected by brazing. Before brazing, it is necessary to completely clean the rust, oil stains, oxides and sand on the surface, and then use flux to further clean the sand holes or micro cracks, and then drop the molten solder into the sand holes or cracks, and wait for the solder to condense. It is welded firmly, and the casting will not leak anymore.


Place the leaking part of the casting at its lowest point, dissolve the metal leak-trapping agent in water, and increase the pressure of the solution to about 1.5 times the working pressure of the casting with the hydrostatic test method. The binder is blocked in the bladder, and as the leakage continues, the binder in the bladder accumulates more and more, and finally the bladder is blocked. After stopping the leakage, keep the pressure for another 20 minutes, then let go of the leak trap and leave it for 24-28 hours to let it dry naturally and the adhesive is cured. Do a test from the beginning to check, and it can be used without leaking.


Use hydrochloric acid corrosion method to eliminate shortcomings such as pores, blisters and cracks. The specific method is to wash the tank with gasoline, and then pour it into a 5%-10% hydrochloric acid solution for a whole day and night, so that the hydrochloric acid and the casting will have a chemical reaction. Because of the replacement effect, the produced ferrous chloride can fill the small blisters. , Cracks and pores. However, the corroded cabinet must be cleaned with a small amount of 0.5%-10% sodium hydroxide aqueous solution to remove the residual hydrochloric acid solution. Atlas air compressor accessories.


Hydrostatic test of the electric heating tube to find out the leakage part, then use a chisel to cut a small groove with a depth of not less than 1.5mm along the crack for degreasing treatment, place the groove surface horizontally, and then use AR-4 glue to fill and plug it. Leakage; in addition to filling the groove, a part of the adhesive can also enter the trachoma under the effect of gravity to complete the leakage.

Note: When using this method, the casting should be boring before filling, and after the filling agent has solidified, a hydraulic test should be carried out to see if there is any leakage.


How to better avoid the corrosion of the electric heating tube, avoid or more reduce the occurrence of similar problems, you need to keep your eyes open to purchase products instead of choosing a qualified manufacturer, so that there is a guarantee of quality. Price advantage and professional technology