+8613456528940

Improper compression ratio of aluminum tube causes poor insulation of electric heating tube

Nov 19, 2021

1. Description


Customers report that the medium and low temperature modified MgO powder produced by our factory has better performance when made into Bondy tubes, but the electric heating tubes made of aluminum tubes are not waterproof, and the insulation decreases after immersion, and the product is poor, which affects normal production. Please inform us promptly Countermeasures and treatment methods.



2. Further inspection of physical objects


product name


Empty aluminum tube size


Aluminum product size


Compression ratio%


Red ink test results


Big pipe


Φ9.53×1


Φ8.04~8.18


14.90


Water ingress


Middle tube


Φ9.53×1


Φ7.92~8.0


16.40


No water


small tube


Φ9.53×1


Φ8.44~8.50


11.11


Imported and national powder are in water


New product


Φ8×0.8


Φ6.6


17.50


No water


New product


Φ×0.8


Φ6.7


16.25


Water ingress


Analyze from the perspective of fans


Normal insulation


Normal withstand voltage


620℃, insulation after 15 minutes


Red ink test results


≤1000MΩ


≤2000v


≤100kMΩ


Water ingress


>1000MΩ


>2000v


>100kMΩ


No water


3. Countermeasures


The compression ratio is greater than 16.4%, and the insulation performance of the electric heating tube is normal.


Send Inquiry