The open hot runner system is more favorable in price than the needle valve hot runner, in addition, the open hot runner system has a simple structure and easy installation, and it is very good for those products that do not have high product appearance requirements.
But at the same time, the problem of wire drawing in the open hot runner system is more than that of the needle valve system, and the wire drawing phenomenon of the open system is generally more common, because the plastic parts are cured first by the skin around the gate when cooling.
If the gate area is not completely cured (continuous input of the gate area temperature), the plastic in the open gate area is pulled out to form a wire drawing phenomenon. The solution is as follows:
1. Lower the hot nozzle temperature, if the hot nozzle is long enough to change to two stages of heating effect will be better.
2. Reduce the size of the gate, thereby reducing the cortex outside the gate.
3. Add a waterway at the gate to reduce the temperature of the gate area and optimize the cooling process at the gate location.
4. Replace the low-power heating ring to reduce the plasticizing capacity of the plastic in the thermal resistance.
5. Optimize injection molding process conditions, such as pressure holding, cooling, setting recycling, etc.