How much power needs to be accurately calculated through its calculation formula to know, only to calculate the specific value to choose a reasonable electric heater equipment, this article mainly explains how its power is calculated, to the way of examples of calculation, convenient for the purchase of manufacturers to reference, in order to better familiarize themselves with the relevant knowledge
The power is to meet the heat generation required by the heating medium and to ensure that the heater can achieve the heating purpose. Since the thermal efficiency of electric heating is approximately 1, it can be considered that the power of the electric heater is the heat generation.
Power selection considerations:
From the initial state, the heating medium is realized to the set temperature (working temperature) according to the specified time requirements;
Under working conditions, the heat generation is sufficient to maintain the temperature of the medium;
There should be a certain safety margin, generally 1.25. The first two will choose the larger power, multiplied by the safety margin is the selected power.
Example 1: A container with an open opening, the dimensions are 500mm wide, 1200mm long, 600mm high, and the weight of the container is 150Kg. It contains 500mm high water, and there is a 50mm insulation layer around the container, and the material is silicate. The water needs to be heated from 15°C within 3 hours
70 °C, then draw 20kg/h of 70 °C water from the container and add the same weight of water. How much power is needed to meet the desired temperature.
Technical data:
1. Specific gravity of water: 1000kg/m3
2. Specific heat of water: 1kcal °C
3. Specific heat of steel: 0.12kcal °C
4. The surface loss of water at 70 °C is 4000W/m2
5. The loss of insulation layer (at 70 °C) is 32W/m2
6. Area of the container: 0.6m2
7. Area of insulation layer: 2.52m2
Power required for initial heating:
Heating of water in the container: C1M1△T = 1×(0.5×1.2×0.5×1000)×(70-15) = 16500 kcal
Heating of the container itself: C2M2△T = 0.12×150× (70-15) = 990 kcal
Average water surface heat loss: 0.6m2 × 4000W/m2 × 3h × 1/2 × 864/1000 = 3110.4 kcal
Average insulation heat loss: 2.52m2 × 32W/m2 × 3h × 1/2 × 864/1000 = 104.5 kcal
(Consider the 20% affluence)
The energy required for initial heating is: (16500 + 990 + 3110.4 + 104.5)×1.2 = 70258.8 kcal°C
Power required for operation:
Heat required to heat the supplementary water: 20kg/h × (70-15)×1kcal°C = 1100kcal
Water surface heat loss: 0.6m2 × 4000W/m2 × 1h × 864/1000 = 2073.6 kcal
Heat loss in the insulation layer: 2.52m2 × 32W/m2 × 1h × 864/1000 = 69.67 kcal