EHD1120-02 Water jacket heater failure

Feb 17, 2023

Liquid heater failure is very normal, because there are many factors that lead to failure, no matter what equipment is there will be a time to cause failure, especially after a long time of use is more likely to fail, these failures can sometimes be solved by themselves, their own can not be solved can be taken to warranty or maintenance are possible, the following mainly introduces the liquid heater common fault solutions, you can come to understand.
  First, the indicator light is not on, generally poor contact or equipment damage will lead to this, if it is poor contact we can plug and unplug several times to see, if not this problem, then it may be equipment damage, equipment damage if the general internal components are damaged or short circuit, at this time we can not disassemble themselves, to find professional repairers to repair, otherwise it is easy to lead to damage again; Second, the thermal efficiency is very slow, in the process of use, you may find that the liquid heater has not burned well for a long time, this time may be unstable current, voltage is too small, and then one is that the dirt on the surface of the metal pipe is too much, should be cleaned up in time, so as not to affect work efficiency; Third, if none of the above is true, you have to find maintenance personnel to repair, if it is a long service life, it is recommended to replace, after all, the time is too long, the work efficiency is also very low, and the insafety is also large.
  Generally speaking, liquid heaters need to be protected by a protection device, one is high temperature protection, a current protection device, if the temperature is too high, sometimes you may forget to unplug the power supply, have been burning inside, to a certain extent will be overheating protection, automatic tripping; There is also a current protection, if there is a short circuit or other factors lead to high current voltage then the current protection device will start, if these devices are useless, it is the quality of the product, generally can be tested, especially the leakage protection device.
  The above mainly talks about the solution to the common fault of the liquid heater, you can go to understand, it is still very helpful to yourself, when in use if there are some small faults can be solved by themselves, generally speaking, the liquid heater is not easy to break, this can still be used with confidence, as long as the safety facilities are in place, the correct use will not be a problem.

 

mmexport1516443969712

mmexport1516526515874

mmexport1516526529973

mmexport1528931440841

Send Inquiry