1.Problems with remote control settings. First check the remote control problem, whether the remote control temperature setting is normal temperature, you can reset the temperature and wait for a period of time to try
1. If the automatic heating function of the smart toilet fails or the water temperature does not meet its adjusted temperature, you need to check the remote control, water tank heating pipe, water temperature sensor, thermal fuse and computer board and other components to determine which parts are faulty.
2. Check whether the temperature setting of the remote control is normal. Wait another 10 minutes after the temperature is set. If it is not hot, unplug the heater and measure the resistance at both ends of the tank heater, which is about 92 ohms, and then measure whether the resistance at both ends of the heater is about 92 ohms. 3. If the fuse is broken, it is necessary to measure the resistance value at both ends of the temperature sensor, the normal range is 25-80K; If it is normal, the computer board is broken and needs to be replaced with a new one.
3. If the automatic hot air function of the smart toilet fails, directly check the drying device and computer board, and measure whether there is a resistance of 89/-4 ohms at both ends of the drying heating wire holder. If not, it means that the drying device is broken. If so, after confirming that it is properly seated, press the dry button and measure whether there is a 220 volt voltage at both ends of the heating wire frame socket.
4. If there is no voltage, the computer board is broken. If you change the drying device, double-check the computer board. Similarly, it needs to be accompanied by professional maintenance personnel, and the parts cannot be replaced blindly, so as not to handle it badly.