Self-controlled temperature electric heat tracing is widely used and is involved in many fields. In actual application, the self-limiting temperature electric heat tracing insulation system will also have some operational problems.



For example, the electric heat tracing insulation system has the phenomenon of uneven temperature, that is, the electric heating system has a period of heating, a period of no heat or low calorific value, and the problem of uneven local heating. Let's analyze this situation.
1. The self-limiting temperature electric cable is dragged during installation, resulting in damage to the insulation of the electric trace, water ingress and moisture in the electric tracing system.
Solution: The self-limiting electric cable outer sheath is damaged, which can only be replaced with a broken electric trace.
Self-limiting temperature electric heat trace
2. The resistance of self-limiting temperature electric cable PTC is damaged
In this case, that is, the performance of the self-limiting temperature electric cable itself changes, and the cable needs to be replaced. We need to choose a regular electric heat trace insulation manufacturer to ensure the quality of electric heat tracing products.
3. The installation of electric heat tracing exceeds the maximum use length
The maximum length of self-controlled temperature electric heat trace is 100 meters, and in actual installation, it is necessary to operate in strict accordance with the maximum use length of electric heat trace. If the maximum length of use of the electric cable is exceeded, it will also cause problems with the electric trace heating.
4. Power supply circuit or voltage problems
If there is a shortage of power, the user can set up a power supply point of the independent electric tracing system to ensure sufficient supply voltage.
5. The installation operation is not standardized
Installation errors occurred during installation operations;
Solution: Strictly follow the design requirements and product operation requirements.